Digital Microscope Color Cameras

Expand your vision in life sciences with a scientific microscope camera. The Olympus range offers a selection of digital microscope color cameras to suit different applications and budgets. Choosing the right balance of specifications is important when selecting the appropriate camera for your needs; our vast range covers applications from general biological research and teaching to pathology, cell culture, embryology, and drug discovery. Our microscope cameras offer a variety of image sensors and pixel sizes, and observation methods include fluorescence, brightfield, and infrared.

At Olympus, we know your image matters, and our digital microscope cameras help you see the details and enhance the quality of your work through cutting-edge optics, superior detail, and fast live imaging.

Get in Touch

https://adobeassets.evidentscientific.com/content/dam/video/video/library/Best_Practices_for_Using_Microscope_Cameras(3)_720.mp4

Digital Microscope Color Cameras

Microscope Digital Camera

DP75

The high-performance DP75 digital microscope camera makes it easy to capture high-resolution brightfield or fluorescence images using a single color camera. It simplifies your microscopy imaging, so you can focus more on your work.

  • Integrated TruAI denoising maximizes the camera’s image quality in real time
  • Exceptional color reproduction, making your images as vivid as looking through the microscope oculars
  • Supports multiple staining combinations and wavelengths up to 1000 nm with a switchable infrared (IR) cut filter

Learn More

Microscope Digital Camera

DP28

Providing color accuracy and 4K resolution, the DP28 digital microscope camera’s powerful features and wide field of view capture images that enhance tasks such as conferencing, teaching, and clinical research. Integrate it seamlessly into your microscopy workflow for improved work efficiency and image quality.

  • 4K resolution
  • Color reproduction that rivals the human eye
  • 8.9-megapixel CMOS sensor

Learn More

Microscope Digital Camera

DP23

Enabling fast, easy capture of high-quality images that can be clearly observed on a large screen, the DP23 microscope digital camera eases routine life science and clinical research, conferencing, or teaching. Integrate it seamlessly into your microscopy workflow and easily share or stream images.

  • Share images using the DP23-AOU network solution
  • Clearly observe live images on a large screen
  • Fast, high-quality imaging for conferences and teaching

Learn More

Microscope Digital Camera

SC180

See and document a sample’s fine details and structures, using the high-resolution SC180 microscope digital camera. Equipped with an 18-megapixel color CMOS sensor, this camera provides fast 4K UHD live imaging displayed at 25 fps.

  • 18-megapixel color CMOS sensor to document fine details
  • Vivid, low-noise images for insightful observations
  • Fast 4K UHD live image

Learn More

Microscope Digital Camera

LC35

Combining quality with affordability, the LC35 digital microscope camera is well suited for standard brightfield imaging applications. Quickly and easily navigate your sample with frame rates of up to 40 fps. Use with any Olympus microscope for simple and seamless integration and setup.

  • Combines good quality images with affordability for an excellent value in standard brightfield imaging applications
  • Navigate your sample quickly with an up to 40 fps frame rate
  • Integrates easily with Olympus microscopes and imaging software

Learn More

Microscope Digital Camera

EP50

Promoting interactive learning, our wireless-enabled EP50 microscope digital camera converts a microscope into a wireless imaging system. Equipped with full stand-alone configuration capabilities, you can control the EP50 camera with a mobile device or PC and stream images to a monitor or projector via WLAN and HDMI.

  • Wireless digital imaging
  • Simultaneous direct output of WLAN and HDMI
  • Full stand-alone configuration available
  • Flexible camera control options for use with mobile devices, PCs, or direct streaming to a monitor/projector with the stand-alone setup

    *This product is not available in some areas

Learn More

Digital Microscope Camera FAQs

What is digital imaging?

Digital imaging is a broad term used to describe the electronic recording of images. You can capture just about anything digitally—from a sunset scene, to a microscope specimen, to a scanned document.

What is a digital image?

A digital image is made of a series of pixels, or picture elements. The computer reads the image file and displays the pixels to form an image on your monitor.

What are the advantages of digital imaging?

There are four core benefits of digital imaging for microscopy:

  • Permanent record: You can make infinite copies of the same digital image without losing image quality. As a result, digital imaging helps you preserve research slides and avoid issues with samples degrading.
  • Image sharing: Digital images can be sent electronically to remote colleagues, helping you save on the shipment fee of mailing a slide for a collaborative project.
  • Image adjustment: Using editing programs like our cellSens imaging software for microscopes, you can easily correct digital images to fix issues like poor contrast and excessive noise in just a few clicks.
  • Analyze quantitatively: Digital imaging provides data for quantitative image analysis, which can help you glean new insights. For instance, you can compare data points to previous imaging results in your database.

How can you improve digital imaging quality for microscopy?

To improve the quality of your microscopy images, choose appropriate optics and cameras with capabilities that match your application.

We offer online resources to help you find microscope objectives and cameras for your experiment. A great place to start is on our blog. Be sure to check out these blog posts for guidance: How to Choose the Right Microscope Objective: 10 Questions to Ask.

Which digital microscope camera capabilities are most important?

There are numerous factors that contribute to image quality. In general, you can start with camera resolution and sensitivity. Sensitivity is how well the camera sensor detects light from the sample. Resolution is the amount of detail a camera can capture. But as we mentioned before, these capabilities must align with your optics, system, and application.

Consider this example: a high-resolution camera is a poor match for a low NA objective since it cannot recover the sample structure information lost through the optics. The reason is that the light spreads wider than the camera’s pixel pitch. In this case, a lower resolution camera will work with a lower NA objective.

Or, say you need to observe in the 700–900 wavelength (nm) range. It is important to select a camera that can detect these longer wavelengths.

There are many other factors to consider, so be sure to check out our white paper: What to Consider When Choosing a Microscope Camera.

Which type of microscope camera sensor should we choose?

There are several types of sensors with their own pros and cons:

  • CCD is an acronym for charge-coupled device. In simple terms, a CCD is a semiconductor chip with light-sensitive areas used as a sensor in digital cameras. CCD sensors work by capturing light and converting it into an electrical charge, which provides the digital pixel data that forms an image. Historically, CCD sensors were the best choice for scientific applications. But as new sensor technology emerges, this older technology is slowly becoming less common.
  • EMCCD stands for electron multiplying charge-coupled devices. EMCCD is a type of CCD sensor that amplifies the low-light signals above the CCD read noise. In conventional CCD, very low signal levels typically fall below the sensor read noise, which limits their imaging capabilities in applications that demand rapid frame-rate capture at extremely low light levels.
    EMCCD cameras are known for their ability to detect weak light—so you may hear them referred to as low-light cameras. Since they feature high sensitivity, they are useful tools for capturing fast biological phenomena at very low lights.
  • CMOS stands for complementary metal-oxide semiconductor and is the successor to CCD technology. The first and most important difference between CMOS and CCD is the readout architecture of the signal electron.
    Thanks to the multi-readout amplifier for an individual photo-sensing diode, CMOS has a significantly faster readout speed than CCD. The tradeoff of fast readout is rolling shutter distortion. Since CMOS scans across the image rapidly to collect data rather than capturing every pixel at once, the exposure time difference can sometimes result in distortion.
    In contrast, CCD sensors can avoid this distortion by collecting incoming photons while storing the charge, enabling it to read out every pixel at the same time.
    While CMOS historically provided a lower signal-to-noise ratio compared to CCD, today you can find many high-quality CMOS cameras. In addition, the introduction of global shutter CMOS overcame the distortion caused by rolling shutter.
  • sCMOS is an acronym for scientific complementary metal-oxide semiconductor—often shortened to scientific CMOS. sCMOS is a type of CMOS sensor with a large pixel size and quiet noise performance. It offers more sensitivity than conventional CMOS. sCMOS sensors are often cooled to minimize the dark current to achieve a higher signal-to-noise ratio, similar to cooled CCD sensors.
    The most important difference between sCMOS and EMCCD cameras is that sCMOS cameras lack the capability for long exposure. EMCCD cameras are preferred for long exposure or bioluminescence imaging applications with weak fluorescence signals, while sCMOS cameras are popular for their ability to work with a variety of imaging techniques.

The most suitable digital camera ultimately depends on your specific application, so don’t hesitate to contact us if you have any questions.

Digital Microscope Color Camera Resources