CellSens

Imaging Software

Contact Us

Overview

cellSens

Intuitive Operation. Seamless Workflow.

The Olympus cellSens platform gives you full control over the display and placement of icons, toolbars, and controls, enabling the software to grow and adapt to meet your evolving research needs.

Get in Touch

cellSens Packages

cellSens Entry

cellSens Entry is the ideal stepping stone for researchers wanting to move into digital image acquisition and documentation, providing all the tools needed for simple image acquisition.

  • Entry
  • Manual Process
  • Encoded Device
  • Database Client
  • Interactive Measurement

*cellSens Entry is not available in some areas.

cellSens Standard

The Olympus cellSens Standard software version builds upon the cellSens Entry package, taking acquisition beyond a single image, with advanced image capture processes (e.g. time lapse) and control of motorized and encoded microscope components.

The Olympus cellSens Standard takes acquisition beyond a single image, with advanced image capture processes (e.g. time lapse) and control of motorized and encoded microscope components.

  • Standard
  • Multiposition
  • Count & Measure
  • Manual Process
  • Database Core
  • Database Client
  • Confluency Checker
  • NetCam
  • Deep Learning

cellSens Dimension

The most versatile member of the Olympus cellSens family is cellSens Dimension, featuring fully automated image acquisition, powerful analysis tools, and so much more.

  • Dimension
  • Multiposition
  • Count & Measure
  • Database Core
  • Database Client
  • NetCam
  • Deep Learning
  • CI Deconvolution
  • Well Plate Navigator
  • Ratio / FRET
  • Photo Manipulation
  • Life Science Analysis
5D Experiment Acquisition

5D Experiment Acquisition

Acquire images in five dimensions using tools, like the Graphic Experiment Manager (GEM) and Well Navigator that help you visualize your data acquisition in a user-friendly way.

Learn more

Image Processing and Sharing

Reveal the true data in your images with TruSight deconvolution and other image processing techniques. Easily share your results with others using Conference Mode or drag and drop data into preconfigured reports.

Learn more

Image Processing and Sharing
Powerful Analysis Tools

Powerful Analysis Tools

Dynamically work with your images to extract the most data for the reliable experimental results. The software’s deep-learning technology (TruAI) offers improved segmentation analysis. Use the Macro Manager to automate entire workflows all the way through image analysis and saving.

Learn more

Customizable User Interface

Choose a recommended layout for image acquisition and analysis or create your own using the My Functions tool set.

Learn more

Customizable User Interface

Need assistance?

Get in Touch

The cellSens software package is not for clinical diagnostic use.

Specifications

cellSens Functions and Optional Solutions

Standard Entry
Layout User experience customization
View Overlay multiple images -
Document groups for side-by-side image comparison
Movie playback
Tile view (multiple images in a single data set shown side-by-side)
Slice view for orthogonal plane viewing of 3D or time-lapse data sets - -
Voxel viewer for isosurface and volumetric rendering of 3D and 4D data sets - -
Image Acquisition Snap/movie acquisition
Time-lapse at specified interval -
Automated multiwavelength -
Z-stack - -
Multidimensional (XYZT and wavelength) - -
Graphical Experiment Manager - -
Manual panoramic imaging (Instant MIA and Manual MIA) Manual Process Manual Process
Multiposition visitation and stage navigator - -
Automated panoramic imaging (auto MIA, requires motorized stage) - -
Instantly create EFI image (manual or motorized Z) Manual Process Manual Process
Simultaneous multicolor Imaging (requires two identical cameras** or image splitter) - -
Live deblurring - -
High dynamic range imaging (HDRI) - -
Multiwell plate acquisition - -
Image Processing Geometry/combine/filter processing -
Fluorescence unmixing - -
Brightfield unmixing - -
Deblurring (No/Nearest Neighbor, Wiener Filter) - -
Kymograph - -
2D deconvolution - -
3D deconvolution (constrained iterative deconvolution with GPU process) - -
Image Analysis Phase analysis - -
Object measurements and classification Count & Measure -
Interactive 2D measurements ✓*
Intensity plot over time/z - -
Colocalization - -
Object counting (manual) -
Object tracking - -
Online ratio and kinetics - -
Ratio analysis (offline) - -
FRET analysis - -
FRAP analysis - -
Cell count and confluency measurements Confluency Checker -
Deep Learning Training of Neural Networks Deep Learning -
Inference using trained Neural Networks (offline/online) Deep Learning or Count & Measure -
Documentation and Collaboration Automatically compose MS Word reports - -
Database image and data management solution for microscopy Database Core -
Open database and load records/documents from database Database Client Database Client
Remoting Remote live image viewing NetCam -

* Three points angle, four points angle, arbitrary line, closed polygon, polyline and perpendicular line only. Interactive 2D measurements option is needed to add other measurement tools and make exporting Excel spreadsheets possible.
** Supported cameras: iXon Ultra 897, Zyla 5.5 (USB 3.0), Zyla 4.2 (USB 3.0/CamLink), Neo, iXon Ultra 888, ImagEM X2, ORCA-Flash 4.0 (V2/V3), Prime 95B, Prime BSI, Prime BSI Express, Sona4.2B-11, ORCA Fusion, ORCS-Fusion BT, ORCA-QUEST

Products with Confirmed Functionality

Dimension Standard Entry
Olympus Camera DP22, DP23, DP23M, DP27, DP28, DP74, DP75, DP80, XM10, UC90, LC20, LC30, LC35, SC50, SC180
Micoscope BX43, BX53, BX63, BX61, BX61WI, IX83, IX73, IX81, SZX16A -
IX81-ZDC, IX81-ZDC2 - -
Peripherals BX-DSU, IX3-DSU, IX3-ZDC, IX3-ZDC2, IX2-DSU, IX2-ZDC, IX2ZDC2, U-CBF, cellTIRF (multiline, single line), USB-ODB converter, Real Time Controller (U-RTCE) - -
Light Source U-LGPS -
Hamamatsu Camera ImagEMX2, ORCA-Flash 4.0 V3, ORCA-Flash 4.0 LT PLUS, ORCA-Flash 4.0 LT3, ORCA-Fusion, ORCA-Fusion BT, ORCA-QUEST - -
ORCA-spark -
Image Splitter W-View Gemini - -
Q-Imaging Camera Retiga 6000 - -
Photometrics Camera Prime (PCI-Express), Prime 95B, Prime BSI, Prime BSI Express, Moment - -
Image Splitter Dual View DV2 / QuadView QV2 - -
Andor Camera iXon Ultra 897, iXon Ultra 888, iXon Life 888, iXon Life 897, Sona4.2B-11,Zyla4.2/Zyla4.2 PLUS (Camera-link,USB3.0), Zyla5.5 (Camera-link 10tap,USB3.0), ZL41 Cell 4.2 (Camera-link,USB3.0), Neo5.5 - -
Vincent Associates Shutter Uniblitz shutter (VCM-D1, VMM-D1, VMM-D3) -
CoolLED Light Source pE-1, pE-2, pE800, pE-4000 - -
pE-300white, pE-300ultra, pE-340fura -
Excelitas Light Source X-Cite120LED, X-Cite XYLIS, X-Cite TURBO - -
Lumencor Light Source SOLA SEII, SEII 365, Spectra X - -
Sutter Shutter, FW Lambda 10-3/10-B - -
Prior Motorized XY Stage ProScan III, Optiscan III Multiposition - -
Shutter, FW, Z-drive ProScan (I, II, III) , Optiscan III - -
Piezo Z (Control via Real Time Controller) NanoScanZ NZ100 - -
Ludl Motorized XY Stage Mac 6000 Multiposition - -
Shutter, FW, Z-drive Mac 6000 - -
Märzhäuser Motorized XY Stage Tango, Pilot Stage Multiposition - -
Z-drive Controller Tango - -
Physik Instrumente Piezo Z (Control via Real Time Controller) PIFOC P-721 - -
Applied Scientific Instrumetation Motorized XY Stage MS-2000 Multiposition - -
Z-drive Controller MS-2000 - -
National Instruments Digital TTL Device NI USB-6501 - -
NI USB-6343 BNC Laser Control - -
Yokogawa CSU CSU-X1, CSU-W1 - -

Regarding the detailed Windows OS compatibility, please contact an Evident sales representative.

Compatible image formats

Read and write
JPEG, JPEG2000, TIFF, BMP, AVI, PNG, VSI, PSD(Adobe Photoshop), Big TIFF, OIR
Read only
GIF, OIF/OIB(FLUOVIEW format), Cell, STK (MetaMorph), MRC (Medical Research Council)

System requirements

OS
Microsoft Windows 10 Professional (64-bit) (22H2), Microsoft Windows 11 Pro (64-bit)(23H2)
OS Language
English, Simplified Chinese, Japanese, German and Italian (Entry and Standard)
CPU
Intel Core i5, Intel Core i7, Intel Xeon Recommended for high-speed image acquisition: QuadCore
RAM
8GB for general applications, 16GB or more is recommended for high-speed image acquisition, 32GB or more is recommended for Deep learning
(For DP23/DP28/DP23M, dual memory is recommended for high frame rate imaging)
HDD
5 GB for installation
Recommended for high speed image acquisition: Solid State Drive (SSD)

Software version update

Version update is available for the next version following the version written on license card. (Exclude updating sub-minor versions) An update that spans 2 or more major or minor versions is required an update license.
Update license provides access to the latest version of cellSens after above period.
Check the latest version for your software

Resources

Application Notes (11)

White Papers (3)

Brochures (2)

Videos (30)

Webinars (1)

eBooks (1)

Infographics (1)

Manuals (17)

Blog (13)

Downloads

Installers and Version Checker

cellSens V4.3 64bit Installer

Download installer

cellSens V4.2.1 64bit Installer

Download installer

cellSens V4.2 64bit Installer

Download installer

cellSens V4.1.1 64bit Installer

Download installer

cellSens V3.2 64bit Installer

Download installer

cellSens V2.3 32bit Installer

Download installer

cellSens V2.3 64bit Installer

Download installer

cellSens V1.18 32bit Installer

Download installer

cellSens V1.18 64bit Installer

Download installer

cellSens V1.16 32bit Installer

Download installer

cellSens V1.16 64bit Installer

Download installer

Release Note

Version 4.3

New function/improvement

Version 4.2.1

New hardware support

New function/improvement

Version 4.2

New hardware support

New function/improvement

Version 4.1.1

New hardware support

Minor bug improvements

Version 4.1

New hardware support

New function/improvement

Version 3.2

New hardware support

New function/improvement

Version 2.3

New hardware support

New function/improvement

Software download

Version 2.2

New hardware support

New function/improvement

Version 2.1

New hardware support

Product portfolio changes

New function/improvement