Inverted Microscopes
Inverted microscopes are valuable pieces of equipment for laboratory cell analysis. Using advanced imaging techniques, inverted microscopes enable you to observe cells for life science research through the use of fluorescence and brightfield observation.
Evident offers a broad selection of routine inverted microscopes, inverted phase contrast microscopes, inverted fluorescence microscopes, and confocal and super resolution inverted microscopes. Designed with ergonomics and precise imaging solutions, our inverted microscopes offer a range of powerful tools to advance your research.
IXplore Inverted Microscope System
IXplore IX85
The IXplore™ IX85 platform delivers an unmatched level of customizability, allowing you to design or build an intelligent, high-performance imaging system that meets your specific goals. And with an industry-leading field number (FN) of 26.5mm plus an array of advanced end-to-end imaging and workflow features, the IXplore™ IX85 means you can capture more than ever before while dramatically reducing your acquisition times.
IXplore IX85 Pro
The foundation of our IXplore™ IX85 Pro system, the IXplore™ IX85 delivers an industry leading FOV and an array of advanced end-to-end imaging features, allowing you to see and capture more than ever before while dramatically reducing acquisition times. Experience exceptional speed, clarity, and reliability with the IXplore™ IX85 microscope system.
IXplore IX85 Live
Designed to reduce photobleaching and phototoxicity, the IXplore™ IX85 Live system is optimized for physiological experiments involving live cell and tissue observation. Offering precise environmental control and enhanced rigidity, it supports long-term cell viability and stability for time-lapse imaging applications, such as in cancer, stem cell, and brain research.
Maintain focus accurately and reliably in time-lapse experiments with TruFocus™ Z-drift compensation system
Discover the real morphology of your cells with Olympus silicone immersion optics
IXplore IX85 Spin
The IXplore™ IX85 Spin system features a spinning disk confocal unit that enables fast 3D image acquisition, a large field of view, and prolonged cell viability in time-lapse experiments. Researchers can use it to perform rapid 3D confocal imaging with high resolution and contrast at greater depths for imaging into thicker samples. The spinning disk also helps to cut down on photobleaching and phototoxicity of samples upon excitation.
TruFocus™ Z-drift compensation system maintains focus for each frame
Precise 3D imaging with improved light collection using X Line™ objectives
Life Science Inverted Microscope FAQs
An inverted microscope is similar to a compound microscope, but the components are positioned in an inverted configuration—thus the name “inverted” microscope. With a compound microscope, the transmitted light source and condenser lens are beneath the stage and specimen. In an inverted microscope, the condenser lens and transmitted light source are placed above the specimen while the objective, fluorescence light source, and mirror turret are positioned below.
The component positioning in an inverted microscope means that transmitted light is directed from above and the resulting image is then viewed from below. This makes inverted microscopes suitable for viewing cell culture vessels, including glass flasks or petri dishes where the specimens adhere to the bottom of the vessel.
As previously stated, an inverted microscope is a microscope with its transmitted light source and condenser above the stage pointing down, while the objectives and turret are below the stage pointing up. Open-frame inverted microscopes, like our IXplore™ Standard and IXplore Pro systems, are great solutions for labs looking to adapt and customize a system to their needs. The systems work with multimodal solutions, such as TIRF illuminators or spinning disk confocal modules, to offer flexible imaging options. When using open-frame inverted microscopes for fluorescence imaging, a dedicated darkroom is usually required to avoid interfering signals from room lights.
If there is not enough space for a dedicated darkroom, an enclosed, all-in-one inverted fluorescence microscope, such as the APEXVIEW™ APX100 digital imaging system, is the best option. An all-in-one inverted fluorescence microscope is an automated research microscope with a box frame that enables users to image under normal lighting conditions. Its automated workflow removes complex steps typically involved in setting up an advanced fluorescence or confocal system, and these compact and versatile inverted microscopes can be placed almost anywhere in a lab or core facility.
Inverted Microscope Resource Videos
IXplore Solutions-Based Microscopy
Each system in the IXplore inverted microscope series is tailored to fit a specific research application to help scientists efficiently accomplish their goals.
Loading a Sample on an Inverted Microscope
This video will show you how to load a sample onto your IX83 inverted microscope using a standard 1 by 3-inch slide.
Silicone Oil Immersion Objectives for Live Cell Imaging
When looking at live cells, the right objectives will enable you to see clearly. This video looks at the ways in which silicone oil immersion objectives achieve precise and higher resolution images during cell and tissue observation.