Laser scanning microscopy is used in biological and materials science research to obtain high-resolution, high-contrast images of a sample. Laser microscopes can scan samples point by point, resulting in optical sectioning that can be used to construct precise 3D images.
Our laser scanning microscopes are designed with a large range of imaging modalities to meet some of the most difficult challenges in life and materials sciences. Offering high sensitivity and speed, our laser scanning microscopes enable live cell imaging, deep tissue observation, and precise sample measurement and analysis. Choose from a range of laser scanning systems suited to a variety of scientific applications—including imaging biological samples in cancer and developmental biology research fields, as well as metallurgical surface roughness evaluation and quality inspection of electronics such as semiconductors and EV batteries. Evident has a solution to meet your specific needs.
Life Science Solutions
FV4000
Confocal Laser Scanning Microscope
- Game-changing dynamic range for imaging from the macro scale to subcellular structures
- Multiplex up to six channels simultaneously with TruSpectral technology
- Redesigned high-speed, high-resolution scanners for fixed and live cell imaging
- Improved depth and photosensitivity with pioneering NIR capabilities and renowned optics
- Peace of mind with the reliable, repeatable SilVIR detector
- Industry leading * ten laser lines with a broader spectral range from 405 nm to 785 nm
*As of October 2023.
FV4000MPE
Multiphoton Laser Scanning Microscope
- Acquire accurate, quantitative image data from the macro scale to subcellular structures
- Obtain more information from a single multicolor image
- Monitor neuron and other essential dynamics with high-speed imaging
SilVIR detector
FLUOVIEW Laser Scanning Microscope Solutions
- Combines a silicon photomultiplier and patented * fast signal processing for lower noise, higher sensitivity, and improved photon resolving capabilities
- High detection efficiency provides superior signal-to-noise to bring weak fluorescence to life
- Capture vivid fluorescence images with no offset adjustments
- Precisely quantify image intensity for more reliable data
*Patent number US11237047
LEXT OLS5100
Confocal Laser Scanning Microscope for Material Analysis
- Guaranteed measurement accuracy of 3D surface shape at the submicron level*
- High-performance optics reduce aberration throughout the entire field of view
- High-resolution image stitching and fast scanning speeds to quickly acquire images
- User-friendly interface and intuitive software enabling operation by all user types
Laser Scanning Microscope FAQs
Laser scanning confocal microscopes are used in life science research across a broad range of live and fixed specimens for molecular and cellular anatomical, physiological, and biochemical studies. Their inherent ability to optically section light enables laser scanning microscopes to achieve accurate high-resolution and high-contrast reconstruction of 3D structures from a series of images obtained at different depths.
To learn more about the uses of confocal microscopy, visit our microscopy resource center.
Confocal microscopy offers several advantages over conventional widefield optical microscopy, including the ability to control depth of field, elimination or reduction of background information away from the focal plane (high signal-to-noise ratio), and the capability to collect serial optical sections from thick specimens. The basic key to the confocal approach is the use of spatial filtering techniques to eliminate out-of-focus light or glare in specimens outside the immediate field of view.
A point-scanning laser confocal microscope creates optical sections of a specimen by scanning a focused laser spot point by point across a field of view. The microscope’s objective then focuses this light on the sample. The photons emitted from the fluorophores in the sample located at the focus point are collected by the objective and relayed back through the scanner, passing through a pinhole that is conjugate to the objective focal plane, causing only the in-focus photons to be detected by the photomultiplier tube. By imaging the photons at each point of the laser position, an image can be reconstructed pixel by pixel.
To learn more about confocal microscopy, visit our microscopy resource center.
Multiphoton microscopy is an excellent technique for deep imaging in thick specimens, especially during in vivo experiments. Strongly focused near-infrared laser pulses penetrate deeper into biological tissues than visible light, as near-infrared light experiences less absorption and scattering. For imaging, a pulsed laser is scanned across the specimen, typically using wavelengths from 700 to 1300 nm for excitation. Multiphoton excitation is inherently localized to the focal plane, thus reducing phototoxicity. More importantly, a confocal pinhole is not required for optical sectioning, so more light signal—including scattered fluorescence photons—can be collected. The results are bright, detailed 3D images from deep within thick specimens.
Discover the Olympus FVMPE-RS™ multiphoton laser scanning microscope.
Overall, resolution is significantly improved in confocal microscopy compared to traditional widefield microscopy techniques. Because resolution in laser scanning microscopy is dependent on the objective’s numerical aperture (NA), it is critical to use high NA objectives to achieve a high-resolution image. Olympus offers a suite of high NA objectives, including our X Line™ objectives, which offer high numerical aperture (NA), image flatness, and chromatic correction to improve image resolution over a larger field of view. For deep tissue imaging, our A Line™ silicone immersion objectives provide a close refractive index match to that of live cells, enabling brighter and higher resolution 3D imaging with minimal spherical aberration.
For increased resolution during deep imaging with our FVMPE-RS multiphoton system, TruResolution™ objectives have an automated correction collar that dynamically compensates for spherical aberration while maintaining accurate focus position. They automatically adjust at every plane of a volume image, delivering sharper and brighter 3D images at depth.
To remove image blur for clearer, sharper high-resolution images during image processing, Olympus has developed specialized TruSight™ 2D and 3D deconvolution algorithms for laser confocal and Olympus Super Resolution (OSR) images.
For studies requiring higher resolution, such as colocalization analysis, the Olympus Super Resolution (OSR) imaging module for the FV3000 system can acquire four fluorescent signals either sequentially or simultaneously with a lateral (X-Y) resolution of approximately 120 nm, nearly doubling the resolution of typical confocal microscopes.
Want to learn more about Olympus Super Resolution?
Laser scanning microscopes can be built into a system according to your budget and application. If you have a limited target object that you want to observe, it is possible to limit the number of lasers, detectors, and types of objectives at an affordable price. It is also possible to upgrade the system by adding necessary units as your research objectives change and develop over time.
Contact your local Olympus representative to discuss our laser scanning confocal systems and get a quote.
Laser Scanning Microscopy Resource Videos
TruResolution Objectives Maximize Resolution in Deep Imaging
This video shows you how TruResolution objectives automatically compensate spherical aberration in every plane of a volume image, delivering sharper and brighter 3D images at depth.
FV3000 Microscope in Cancer Research
In this video, Dr. Yuji Mishima of the Japanese Foundation for Cancer Research explains fluorescent imaging as a tool for research.