Automated Organoid Imaging and
High-Throughput 3D Analysis
Discover an imaging system that helps alleviate the burden from the operator, enabling rapid detection and automated sequential imaging of 3D objects.
Automated Macro-to-Micro Imaging
When imaging 3D specimens such as organoids or thick tissue samples, locating target objects can be a challenging and slow process. This task is especially time consuming in a multiple-chambered vessel or multiwell plates. Using this automated acquisition process, you can dramatically reduce the time you spend operating the microscope:
- The FV4000 confocal laser scanning microscope automatically captures images at low magnification.
- Then the FV software’s Macro-to-Micro module detects your objects of interest in the vessel or well and captures them at high magnification.
Observation Condition | For samples requiring 600 µm working distance or less | For imaging samples in plastic-bottomed microplates | For larger organoids requiring a WD greater than 600 µm |
---|---|---|---|
UPLXAPO20X | UCPLFLN20XPH | UPLSAPO30XS | |
Numerical Aperture (NA) | 0.8 | 0.7 | 1.05 |
Working Distance (WD) | 600 μm | 800 μm–1800 μm | 800 μm |
Field of View (FOV) | 900 μm | 900 μm | 540 μm |
Immersion Medium | Air/Dry | Air/Dry | Silicone Oil |
Refractive Index (RI) | 1.0 | 1.0 | 1.4 |
High-Quality Images with X Line and A Line Objectives
Olympus offers several objectives with features that help solve the challenges of organoid imaging conditions and observation requirements.
For organoids on a glass- or film-bottomed microplate, we recommend the UPLXAPO20X objective from the award-winning X Line™ series. This 20X objective provides an excellent balance of resolution, field of view, and depth of focus. It features a high NA of 0.8, a 600 µm working distance, and air immersion, which makes it easy to image across a microplate. For deep-tissue imaging applications, we recommend the UPLSAPO30XS 30X silicone oil immersion objective, which can reach up to 800 µm deep into your sample. Offering an impressive working distance range of 800 µm to 1800 µm, our UCPLFLN20XPH objective also enables imaging through plastic-bottomed vessels.
High-Throughput 3D Image Analysis
NoviSight™ 3D cell analysis software is optimized to analyze 3D models on microplates. Once target objects are detected in 3D, you can examine the data using different dimensional views, including:
- Statistical information (1D)
- XY image (2D)
- Voxel (3D)
This flexibility enables you to evaluate the experiment results with high throughput and in a quantitative manner.
“Automatic organoid imaging enables researchers to perform targeted imaging, which allows for fast detection and sequential high-magnification imaging of 3D objects. This ultimately contributes to the efficiency of our imaging workflow to examine phenotypic changes of patient-derived organoids in response to drug perturbations.
NoviSight software provides seamless and interactive 3D organoid image analysis by measuring multiple parameters with high reproducibility, which is key for high-content imaging and high-throughput drug screening.”
Seungil Kim, PhD, Microscopy Team Manager
Lawrence J. Ellison Institute for Transformative Medicine of University of Southern California
Map at 4X
Single slice at 20X
Maximum intensity projection at 20X
Related Products
https://main--eds-evident-website--evident-scientific.hlx.live/en/laser-scanning/fv4000/
Confocal Laser Scanning Microscope
FV4000
- Game-changing dynamic range for imaging from the macro scale to subcellular structures
- Multiplex up to six channels simultaneously with TruSpectral technology
- Redesigned high-speed, high-resolution scanners for fixed and live cell imaging
- Improved depth and photosensitivity with pioneering NIR capabilities and renowned optics
- Peace of mind with the reliable, repeatable SilVIR detector
- Industry leading* ten laser lines with a broader spectral range from 405 nm to 785 nm
*As of October 2023.
https://main--eds-evident-website--evident-scientific.hlx.live/en/laser-scanning/fv4000MPE/
Multiphoton Laser Scanning Microscope
FV4000MPE
- Acquire accurate, quantitative image data from the macro scale to subcellular structures
- Obtain more information from a single multicolor image
- Monitor neuron and other essential dynamics with high-speed imaging
https://main--eds-evident-website--evident-scientific.hlx.live/en/software/novisight/
3D Cell Analysis Software
NoviSight
NoviSight 3D cell analysis software provides statistical data for spheroids and 3D objects in microplate-based experiments. Use it to quantify cell activity in 3D, easily capture rare cell events, obtain accurate cell counts, and improve detection sensitivity. NoviSight software works with a range of imaging techniques, including point-scan confocal imaging, two-photon imaging, spinning disk confocal imaging, and super resolution live cell imaging.
- Fast 3D image recognition from whole structures to subcellular features
- Accurate statistical analysis
- Equipped with a variety of ready-to-use default assays or easily design your own