Application Notes

Contact Us

About Surface Roughness

How to Define Surface Roughness

Surface roughness indicates the condition of processed surfaces. Surface conditions are determined by visual appearance and tactile feel. Consider the following examples:

The difference in both appearance and texture are derived from the topographical variation, or irregularities, on the surface of the object. It is an increasingly important characteristic to track and quantify for quality assurance purposes.

These irregularities are what determines the roughness of a surface. Surface roughness is a numerical scale of the surface condition that does not depend on visual or tactile sensation. By taking several measurements of the surface, such as the peak heights and the valley depths, individual surface roughness values (such as Sa, Sq, and Sz) and their relationships can be determined and a quantitative definition for a surface quality can be produced.

Facial irregularities on components and materials are either created intentionally or produced by various factors including the vibration of cutting tools, the bite of the edge used, or the physical properties of the material. Irregularities have diverse sizes and shapes and overlap in numerous layers; the concavities/convexities affect the quality and functionality of the object's surface.

Consequently, the irregularity impacts the performance of the resulting product. In the case of assembly components, the surface feature affects the characteristics of the final product, including friction, durability, operating noise, energy consumption, and air tightness. The surface features also influence the product’s quality, such as a paper product’s ability to hold ink/pigment or varnish.

Why Does Surface Roughness Need to be Measured?

The size and configuration of features have a significant influence on the quality and functionality of processed surfaces and the performance of the final products. Consequently, measuring surface roughness is important to meet high performance standards for end products.

How to Measure Surface Roughness

Surface irregularities are measured by classifying the height/depth and intervals of surface features to evaluate their concavity/convexity. The results are then analyzed in accordance with predetermined methods, subject to a calculation based on industrial quantification.

The favorable or adverse influence of surface roughness is determined by the size and shape of the irregularities and the use of the product.

The level of roughness must be managed based on the desired quality and performance of the surface.

The measurement of the roughness of surfaces and the evaluation of surface roughness is an old concept with numerous established parameters indicating various roughness criteria. The progress of processing technology and the introduction of advanced measurement instruments enable the evaluation of diverse aspects of surface roughness.

Remote visual inspection

Methods to Measure Surface Roughness

Measuring the surface roughness of components and industrial products and the qualitative management of the resulting data are increasing with the evolution of nanotechnology and the higher performance demands and smaller size of electronic devices. Conventional stylus roughness gauges are designed to acquire height information through mechanical contact with the surface finish being measured. These devices can broadly measure surface height, features, and the superficial condition of the surface finish.

However, the ever-increasing improvements to manufacturing processes have resulted in a growing number of soft samples, such as films, and surface features that are smaller than the tip of the stylus probe. These material advancements have led to the demand for noncontact and nondestructive measurement techniques, from linear measurement to precise area measurement.

To meet these nano-level surface roughness measurement demands, laser microscopes have been developed as surface roughness measuring instruments capable of providing an accurate, noncontact 3D surface roughness measurement of the surface features of a sample under ambient conditions.

Surface Roughness Technical Terminology

Primary profile curve: the profile curve obtained by applying a low-pass filter with a cutoff value of λs to the primary profile measured.

Roughness profile: the profile curve derived from the primary profile by suppressing the longest wavelength components using a high-pass filter with a cutoff value of λc.

Waviness profile: the profile curve obtained by sequential application of profile filters with cutoff values of λf and λc to the primary profile.

Sampling length: the length in the direction of the measured axis used for the determination of profile characteristics.

Evaluation length: the length in the direction of the measured axis used for assessing the profile under evaluation.

Conceptual drawing of the profile method

Conceptual drawing of the profile method

Learn More about Surface Roughness Measurement

> Profile method (line roughness) parameters
> Areal method (areal roughness) parameters
> Evaluating roughness parameters
> Methods of measuring surface roughness
> International standarization
> Technical terminology glossaries
> Essentials of surface roughness evaluation using laser microscopy

Download the Roughness Measurement Guidebook

Download Roughness Measurement Guidebook
  • Laser microscopes and roughness measurement
  • Essentials of surface roughness evaluation using laser microscopy
  • Selecting the roughness parameter
  • Explanation of roughness parameters (profile method, areal method)
  • Advantages of a laser microscope for surface roughness measurement

Download Now

With its advanced 3D laser confocal scanning technology, Olympus’ LEXT OLS5100 3D measuring microscope raises your roughness measurement to a higher level. Quickly scan and detect single-nanometer surface features at ambient conditions to accurately measure the depth and height of irregularities. Use its powerful 3D image stitching to expand the field of view. Improve productivity through the microscope’s streamlined workflow and the efficiency of its noncontact measurements, providing high-resolution, high-precision images with complementary optical information. exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat.

VIEW PRODUCT DETAILS

Advantages of the OLS5100 Microscope for Surface Roughness Measurement

Noncontact, no damage on specimen

No preliminary preparation required.
Simply place the sample on the stage and begin measurement.

Acquire roughness information from an entire plane

Three types of information can be acquired simultaneously, from an entire plane.

Accurate measurement by capturing fine irregularities

The 405 nm / 0.4 μm diameter laser beam scans fine features without distortion.

Applications

Surface Roughness Measurement Application Solutions

Electronic Device

Roughness Evaluation of the Inner Lead of a Lead Frame / Surface roughness measurement of a micro area using a laser microscope

Measuring the Surface Roughness of Lithium-Ion Battery Electrode Collectors

Measuring the Roughness of Lithium-Ion Battery Electrodes Using a Laser Microscope

Measuring the Surface Roughness of a Lead Frame Die Pad

Copper Foil Surface Roughness for 5G Printed Circuit Boards

Machined Parts

Measuring the Surface Roughness of Ball Bearings using the Olympus OLS5000 Laser Confocal Microscope

Roughness Measurement of Sliding Metal Surfaces using the Olympus OLS5000 Laser Confocal Microscope

Shape and surface roughness measurements of screws / Surface roughness measurement using a laser microscope

Surface profile evaluation for thermal spraying / Surface roughness measurement using a laser microscope

Inner/outer wall roughness of a metal tube

Automotive Parts

Roughness Evaluation of the Side Surface of Piston Rings

3D Evaluation of Automobile Door Switch Embossing Using the LEXT OLS5000 Laser Microscope

Surface profile measurement of oil seals using a laser microscope

Surface roughness measurement of the cam lobe of a camshaft

Roughness Measurement of Gear Teeth for Eco-Friendly Cars

Evaluating the Anti-Glare Property of a Speedometer Cover with High Precision Using a Laser Scanning 3D Microscope

Medical Device

Using our LEXT™ OLS5000 Laser Confocal Microscope to Measure Surface Roughness on the Metal Part of Dental Implants

Measuring the roughness of the inner wall of medical tubing

Metal Fabrication

Surface Roughness Measurement for Stainless Steel / Micro surface roughness measurement using a laser microscope

Materials

Gaining the Edge: The Design and Development of a Device Equipped to Create 3D Ski Edge Measurements

Static Electricity and Surface Roughness in Films: An Experiment

Water Repellency and Surface Roughness in Films: Example Using a Yogurt Lid